58 research outputs found

    Safe procedures despite ultra low radiation doses during catheter ablations of atrial and ventricular arrhythmias—A multicenter experience

    Get PDF
    Introduction: Despite the development of non-fluoroscopic catheter visualization options, fluoroscopy is still used in most ablation procedures. The aim of this multicenter study was to evaluate the safety and efficacy of a new ultra-low dose radiation protocol for EP procedures in a large number of patients. Methods and results: A total of 3462 consecutive patients (male 1926 (55.6%), age 64.4 ± 14.0 years, BMI 26.65 ± 4.70) undergoing radiofrequency ablation (left atrial (n = 2316 [66.9%], right atrial (n = 675 [19.5%], or ventricular (n = 471 [13.6%]) in three German centers were included in the analysis. Procedures were performed using a new ultra-low dose protocol operating at 8nGy for fluoroscopy and 36nGy for cine-loops. Additionally a very low framerate (2-3FPS) was used. Using the new protocol very low Air kerma-area product (KAP) values were achieved for left atrial ablations (104.25 ± 84.22 μGym2 ), right atrial ablations (70.98 ± 94.79 μGym2 ) and ablations for ventricular tachycardias or PVCs (78.62 ± 66.59 μGym2 ). Acute procedural success was achieved in 3289/3388 (97.1%) while the rate of major complications was very low compared to previously published studies not using low dose settings (n = 20, 0.6%). Conclusion: The ultra-low dose, low framerate protocol leads to very low radiation doses for all EP procedures while neither procedural time, fluoroscopy time nor success or complication rates were compromised. When compared to current real-world Air KAP data the new ultra-low dose fluoroscopy protocol reduces radiation exposure by more than 90%

    Biomarker-based diagnosis of pacemaker and implantable cardioverter defibrillator pocket infections: A prospective, multicentre, case control evaluation

    Get PDF
    Background: The use of cardiac implantable electronic devices (CIED) has risen steadily, yet the rate of cardiac device infections (CDI) has disproportionately increased. Amongst all cardiac device infections, the pocket infection is the most challenging diagnosis. Therefore, we aimed to improve diagnosis of such pocket infection by identifying relevant biomarkers. Methods: We enrolled 25 consecutive patients with invasively and microbiologically confirmed pocket infection. None of the patients had any confounding conditions. Pre-operative levels of 14 biomarkers were compared in infected and control (n = 50) patients. Our selected biomarkers included white blood cell count (WBC), C-reactive protein (CRP), procalcitonin (PCT), lipopolysaccharide binding protein, high-sensitivity C-reactive protein (HS-CRP), polymorphonuclear-elastase, presepsin, various interleukins, tumor necrosis factor a (TNF-a), and granulocyte macrophage colony-stimulating factor (GM-CSF). Results: Of the 25 patients with isolated pocket infection (70 13years, 76% male, 40% ICDs), none presented with leukocytosis. In contrast, they had higher serum levels of HS-CRP (p = 0.019) and PCT (p = 0.010) than control patients. Median PCT-level was 0.06 ng/mL (IQR 0.03-0.07 ng/mL) in the study group versus 0.03 ng/mL (IQR 0.02-0.04 ng/mL) in controls. An optimized PCT cut-off value of 0.05 ng/mL suggests pocket infection with a sensitivity of 60% and specificity of 82%. In addition TNF-alpha- and GM-CSF-levels were lower in the study group. Other biomarkers did not differ between groups. Conclusion: Diagnosis of isolated pocket infections requires clinical awareness, physical examination, evaluation of blood cultures and echocardiography assessment. Nevertheless, measurement of PCT- and HS-CRP-levels can aid diagnosis. However, no conclusion can be drawn from normal WBC-values

    Automated segmentation of the atrial region and fossa ovalis towards computer-aided planning of inter-atrial wall interventions

    Get PDF
    Image-fusion strategies have been applied to improve inter-atrial septal (IAS) wall minimally-invasive interventions. Hereto, several landmarks are initially identified on richly-detailed datasets throughout the planning stage and then combined with intra-operative images, enhancing the relevant structures and easing the procedure. Nevertheless, such planning is still performed manually, which is time-consuming and not necessarily reproducible, hampering its regular application. In this article, we present a novel automatic strategy to segment the atrial region (left/right atrium and aortic tract) and the fossa ovalis (FO).Fundacão para a Ciência e a Tecnologia (FCT), in Portugal, and the European Social Found, European Union, for funding support through the “Programa Operacional Capital Humano” (POCH) in the scope of the PhD grants SFRH/BD/95438/2013 (P. Morais) and SFRH/BD/93443/2013 (S. Queirós). This work was funded by projects NORTE-01-0145-FEDER-000013, NORTE-01-0145-FEDER-000022 and NORTE-01-0145-FEDER-024300, supported by Northern Portugal Regional Operational Programme (Norte2020), under the Portugal 2020 Partnership Agreement, through the European Regional Development Fund (FEDER), and also been funded by FEDER funds, through Competitiveness Factors Operational Programme (COMPETE), and by national funds, through the FCT, under the scope of the project POCI-01-0145-FEDER-007038info:eu-repo/semantics/publishedVersio

    A competitive strategy for atrial and aortic tract segmentation based on deformable models

    Get PDF
    Multiple strategies have previously been described for atrial region (i.e. atrial bodies and aortic tract) segmentation. Although these techniques have proven their accuracy, inadequate results in the mid atrial walls are common, restricting their application for specific cardiac interventions. In this work, we introduce a novel competitive strategy to perform atrial region segmentation with correct delineation of the thin mid walls, and integrated it into the B-spline Explicit Active Surfaces framework. A double stage segmentation process is used, which starts with a fast contour growing followed by a refinement stage with local descriptors. Independent functions are used to define each region, being afterward combined to compete for the optimal boundary. The competition locally constrains the surface evolution, prevents overlaps and allows refinement to the walls. Three different scenarios were used to demonstrate the advantages of the proposed approach, through the evaluation of its segmentation accuracy, and its performance for heterogeneous mid walls. Both computed tomography and magnetic resonance imaging datasets were used, presenting results similar to the state-of-the-art methods for both atria and aorta. The competitive strategy showed its superior performance with statistically significant differences against the traditional free-evolution approach in cases with bad image quality or missed atrial/aortic walls. Moreover, only the competitive approach was able to accurately segment the atrial/aortic wall. Overall, the proposed strategy showed to be suitable for atrial region segmentation with a correct segmentation of the mid thin walls, demonstrating its added value with respect to the traditional techniques.The authors acknowledge Fundacao para a Ciencia e a Tecnologia (FCT), in Portugal, and the European Social Found, European Union, for funding support through the "Programa Operacional Capital Humano" (POCH) in the scope of the PhD grants SFRH/BD/95438/2013 (P. Morais) and SFRH/BD/93443/2013 (S. Queiros).Authors gratefully acknowledge the funding of projects NORTE-01-0145-FEDER-000013 and NORTE-01-0145-FEDER-000022, co-financed by "Programa Operacional Regional do Norte" (NORTE2020), through "Fundo Europeu de Desenvolvimento Regional" (FEDER).info:eu-repo/semantics/publishedVersio

    Prevalence and Treatment Outcomes of Arrhythmias in Patients with Single Ventricle Physiology over the Age of 40 Years

    No full text
    Background: Arrhythmias are a well known complication in patients with single ventricle physiology (SVP). However, there is still a lack of data regarding arrhythmias in older patients. The aim of this study was to analyze arrhythmia type and frequency, treatment and recurrence rates in patients with SVP over the age of 40 years. Methods: Data was obtained retrospectively from clinical records. All patients > 40 years with SVP with arrhythmias between 2005 and 2018 were included in the study. Treatment was classified as medical, interventional (electrophysiological studies (EPS) in combination with catheter ablation) or direct current cardioversion (DCCV). Results: Altogether, 29 patients (11 female; mean 47.5 ± 4.6 years) with 85 arrhythmia episodes were identified. The median follow-up time was 6.3 years. Cavo-tricuspid (CTI) and non-CTI related intra-atrial reentrant tachycardia (IART) and atrial fibrillation (AF) were most common (48.2% and 37.6%, respectively). In total, 18 EPS/ablations were performed in 9 patients and 52 DCCVs in 20 patients. Acute success was 98% for DCCV and 72.2% for EPS/ablation. Recurrence rate was high (70% for DCCV and 55% for EPS). AT recurrences occurred after a median of 8 and 2.5 months, respectively. On multivariate analyses, age was the only risk factor for arrhythmia recurrence (HR 0.58, 95% C.I. 0.43–0.78, p < 0.0001). Pacemaker implantation was necessary in seven patients (AV block n = 4, sinus node dysfunction n = 3) and one patient received an ICD for secondary prophylaxis. Sudden death occurred in three patients. Conclusions: The most common arrhythmias in patients with SVP > 40 years are IART and AF. Arrhythmia recurrence following EPS or DCCV is frequent. Older age is an independent risk factor for arrhythmia recurrence

    Recent advances in cardiac mapping techniques

    No full text

    Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow®) with contact force measurement (Smarttouch®)

    Get PDF
    Introduction: Pulmonary vein reconnection after pulmonary vein isolation (PVI) is a significant problem in the treatment of paroxysmal atrial fibrillation (AF). We report about patients who underwent contact force (CF) guided PVI using CF catheter and compared them to patients with PVI using an ablation catheter with enhanced tip irrigation. Methods: A total of 59 patients were included in the analysis. In 30 patients circumferential PVI was performed using the Thermocool Smarttouch® ablation catheter (ST) whereas in 29 patients circumferential PVI using the Thermocool Surround Flow SF® ablation catheter (SF) was performed. Patients were compared in regard to procedure time, fluoroscopy time/dose as well as RF-application duration and completeness of PVI. Adverse events (pericardial effusion, PV stenosis, stroke, death) were evaluated. The presence of sinus rhythm off antiarrhythmic medication was assessed during 6 months follow-up using multiple 7 day Holter-ECGs. Results: In both groups, all PVs were isolated without serious adverse events. Procedure time was 2.15 ± 0.5 h (ST) vs. 2.37 ± 1.13 h (SF) (p = 0.19). Duration of RF-applications was 46.6 ± 18 min (ST) and 49.8 ± 19 min (SF) (p = 0.52). Fluoroscopy time was 25.2 ± 13 min (ST) vs. 29 ± 18 min (SF), fluoroscopy dose 2675.6 ± 1658 versus 3038.3 ± 1997 cGym2 (p = 0.36 and 0.46 respectively). Sinus rhythm off antiarrhythmic medication validated with 7 day Holter ECGs was present in both groups in 72% of patients after 6 months of follow up. Conclusion: PVI using the new contact force catheter is safe and effective in patients with paroxysmal AF
    corecore